YS-U20S24H AC110-220 to DC 24V1A Switching Power Supply Module 24W DC Stabilized Conterver Power Supply
- Stock: In Stock
- Model: EB0044768
- SKU: EB0044768
- Power: 24W
- Voltage: DC 24V
Precise details:
>>>Manual: Click here to open<<<
Features:
-Universal voltage input: AC85-265V AC
-With overload, short circuit, over temperature protection function
-Comply with safety regulations, switch operating frequency 60KHz
-Full load aging test
-High output voltage accuracy, output voltage potentiometer can be finely adjusted
Specifications:
Model | YS-U20S24H | |
Output characteristics | Output voltage | 24V |
Rated current | 1000mA | |
Current range | 0-1000mA | |
Ripple | <100mVp-p | |
Output accuracy | ±1% | |
Voltage regulation rate | <±1% | |
Load regulation rate | ±1.2% | |
Rated power | 24W | |
Adjustable output range | 21.5-26.5V | |
Setup, rise, hold time | 50ms、30ms、30ms/24VDC | |
Input characteristics | Input voltage range | AC85-265V |
Input current | 0.05A-0.3A | |
Frequency range | 50Hz-65Hz | |
Effectiveness | >85% | |
Start impact circuit | COLD START<0.3A | |
Leakage current | <0.6mA/220VAC | |
Protection characteristics | Over power protection | 130-150% rated power, automatic recoveri after fault removal |
Overvoltage protection | DC OUT >130% | |
Output short circuit protection | Intermittent power interruption to eliminate short-circuit power recoveri | |
Over temperature protection | PWM chip node temperature>100℃ close control | |
Environmental parameters | Working temperature, humidity | -20℃ to +60℃@100%LOAD,+60℃LOAD:20%-90%RH |
Storage temperature and humidity | -40℃ to +105℃ 10%-95%RH | |
Safety and EMC standards | EMI. Safety standards | GB17625.2;GB17626.4;En55022 CLASSB |
Withstand voltage | I/P-O/P:3.0KVAV 1min | |
Insulation resistance | I/P-O/P;500VDV/100M Ohms | |
Other | Dimensions (length x width x height) | 76*40*23.5mm |
Weight | 39g |
Note:
1. All parameters are measured under the conditions of rated voltage AC220V input, rated load, environment 25℃ and humidity 70%.
2. Accuracy: including setting error, voltage adjustment rate, load adjustment rate
3. Ripple test: Connect the power supply and the load with a 30cm stranded wire, connect 0.1uF and 47uF capacitors in parallel at the load end, and measure with a 20MH oscilloscope at the load end.
4. Voltage regulation rate: under rated load conditions, the input voltage changes from low to high.
5. Load regulation rate: the measured output changes from 0% to 100% load.
6. Each channel can output the maximum current, but the total load cannot exceed the maximum output power.
Package Included:
1 x YS-U20S24H AC110-220 to DC 24V1A Switching Power Supply Module
>>>Manual: Click here to open<<<
Features:
-Universal voltage input: AC85-265V AC
-With overload, short circuit, over temperature protection function
-Comply with safety regulations, switch operating frequency 60KHz
-Full load aging test
-High output voltage accuracy, output voltage potentiometer can be finely adjusted
Specifications:
Model | YS-U20S24H | |
Output characteristics | Output voltage | 24V |
Rated current | 1000mA | |
Current range | 0-1000mA | |
Ripple | <100mVp-p | |
Output accuracy | ±1% | |
Voltage regulation rate | <±1% | |
Load regulation rate | ±1.2% | |
Rated power | 24W | |
Adjustable output range | 21.5-26.5V | |
Setup, rise, hold time | 50ms、30ms、30ms/24VDC | |
Input characteristics | Input voltage range | AC85-265V |
Input current | 0.05A-0.3A | |
Frequency range | 50Hz-65Hz | |
Effectiveness | >85% | |
Start impact circuit | COLD START<0.3A | |
Leakage current | <0.6mA/220VAC | |
Protection characteristics | Over power protection | 130-150% rated power, automatic recoveri after fault removal |
Overvoltage protection | DC OUT >130% | |
Output short circuit protection | Intermittent power interruption to eliminate short-circuit power recoveri | |
Over temperature protection | PWM chip node temperature>100℃ close control | |
Environmental parameters | Working temperature, humidity | -20℃ to +60℃@100%LOAD,+60℃LOAD:20%-90%RH |
Storage temperature and humidity | -40℃ to +105℃ 10%-95%RH | |
Safety and EMC standards | EMI. Safety standards | GB17625.2;GB17626.4;En55022 CLASSB |
Withstand voltage | I/P-O/P:3.0KVAV 1min | |
Insulation resistance | I/P-O/P;500VDV/100M Ohms | |
Other | Dimensions (length x width x height) | 76*40*23.5mm |
Weight | 39g |
Note:
1. All parameters are measured under the conditions of rated voltage AC220V input, rated load, environment 25℃ and humidity 70%.
2. Accuracy: including setting error, voltage adjustment rate, load adjustment rate
3. Ripple test: Connect the power supply and the load with a 30cm stranded wire, connect 0.1uF and 47uF capacitors in parallel at the load end, and measure with a 20MH oscilloscope at the load end.
4. Voltage regulation rate: under rated load conditions, the input voltage changes from low to high.
5. Load regulation rate: the measured output changes from 0% to 100% load.
6. Each channel can output the maximum current, but the total load cannot exceed the maximum output power.
Package Included:
1 x YS-U20S24H AC110-220 to DC 24V1A Switching Power Supply Module
Shipping Time
After you successfully placed an order at RenhotecIC.com, you will receive a confirmation email with your invoice. Once your order is shipped, you will be emailed with the tracking information of your package. Also, you can choose your preferred shipping method during the checkout process. Kindly advise: please select DHL/FedEx if you need our product urgently.
The timeline of the whole shipping process is shown below:
The total delivery time is calculated from the time your order is successfully placed to the time received. Total delivery time is broken down into processing time and shipping time.
Processing time: The time it takes to prepare your item(s), includes preparing your items, performing quality inspections, and packaging for shipment. Normally, the processing time is 1-3 days (Only include Monday to Saturday ) after getting your order.
Shipping time: The time for your item(s) to travel from our warehouse to your destination. The shipping time depends on the shipping method you chose. Please refer to the shipping rate section for details.
Shipping Rates
You could choose the shipping method based on your preference during checkout, different shipping methods will apply different rates and shipping times. Please check the following chart for detail:
You could choose the shipping method based on your preference during checkout, different shipping methods will apply different rates and shipping times. Please check the following chart for detail:
Shipping Method | Shipping Rates | Shipping Times |
Flat Shipping (Promotion) | $10 | About 5-30 Working Days to Worldwide (Only include Monday to Saturday ) |
Standard Express(0.5KG starting price listed) | Based On Weights | About 5-15 Working Days to Worldwide (Only include Monday to Saturday ) |
Priority Express (0.5KG starting price listed) | Based On Weights | About 3-7 Working Days to Worldwide (Only include Monday to Saturday ) |
In addition, the transit time depends on where you're located, the shipping method you choose, and where your package comes from. We will keep you informed of any problems here to help you get your order as soon as possible.
If you want to know more information, please contact the customer service by contact form or sales@renhotecic.com. We will settle your problem as soon as possible. Enjoy shopping!