Menu
Your Cart

XY-WTH1 DC 6-30V Temperature and Humidity Controller Module Wet Control Switch Constant Sensor Dual Output Thermostat

XY-WTH1 DC 6-30V Temperature and Humidity Controller Module Wet Control Switch Constant Sensor Dual Output Thermostat
XY-WTH1 DC 6-30V Temperature and Humidity Controller Module Wet Control Switch Constant Sensor Dual Output Thermostat
XY-WTH1 DC 6-30V Temperature and Humidity Controller Module Wet Control Switch Constant Sensor Dual Output Thermostat
XY-WTH1 DC 6-30V Temperature and Humidity Controller Module Wet Control Switch Constant Sensor Dual Output Thermostat
XY-WTH1 DC 6-30V Temperature and Humidity Controller Module Wet Control Switch Constant Sensor Dual Output Thermostat
XY-WTH1 DC 6-30V Temperature and Humidity Controller Module Wet Control Switch Constant Sensor Dual Output Thermostat
XY-WTH1 DC 6-30V Temperature and Humidity Controller Module Wet Control Switch Constant Sensor Dual Output Thermostat
XY-WTH1 DC 6-30V Temperature and Humidity Controller Module Wet Control Switch Constant Sensor Dual Output Thermostat
XY-WTH1 DC 6-30V Temperature and Humidity Controller Module Wet Control Switch Constant Sensor Dual Output Thermostat
XY-WTH1 DC 6-30V Temperature and Humidity Controller Module Wet Control Switch Constant Sensor Dual Output Thermostat
XY-WTH1 DC 6-30V Temperature and Humidity Controller Module Wet Control Switch Constant Sensor Dual Output Thermostat
$24.99
Ex Tax: $24.99
  • Stock: In Stock
  • Model: EB0046024
  • SKU: EB0046024
User Manual: Click here to open

Feature:


Model: XY-WTH1
Temperature range: -20 ° C ~ 60 ° C
Humidity range: 00%~100%RH
Control accuracy: 0.1 °C 0.1% RH
Detection probe: integrated sensor
Output type: relay output
Output capacity: up to 10A

Function:
 
Product features are two main types of classification: the functions of temperature and humidity.
The function of temperature are as follows:
 
1. The automatic identification of work mode:
The system automatically according to the start/stop temperature, identify work mode;
Start temperature > stop temperature, cooling mode'C'.
Start temperature < stop temperature, heating mode 'H'.
 
2. Cooling mode:
When the temperature≥Start temperature, relay conduction, red led on, refrigeration equipment begin to work;
When the temperature≤Stop temperature, relay disconnect, red led off, refrigeration equipment stop to work;
 
3. Heating mode:
When the temperature≤Start temperature, relay conduction, red led on, heating equipment begin to work;
When the temperature≥Stop temperature, relay disconnect, red led off, heating equipment stop to work;
 
4. Temperature correction function OFE (-10.0 ~ 10℃):
The system is working for a long time and may be biased, through this function correctly, the actual temperature = measuring temperature + calibration value;

How to set the start/stop temperature:
 
1. In the running interface, Long Press ' TM+ ' key more than 3 seconds, into the start temperature settings interface, can be modified by TM+ TM-key, to be modified, waiting for 6s automatic exit and save;
2. In the running interface, Long Press ' TM-' key more than 3 seconds, into the stop temperature settings interface, can be modified by TM+ TM-key, to be modified after the parameters, waiting for 6s automatic exit and save;

The humidity function is as follows:
 
1. The automatic identification of work mode:
The system automatically according to the start/stop humidity, identify work mode;
Start humidity > stop humidity, dehumidification mode'D'.
Start humidity < stop humidity, humidification mode 'E'.
 
2. Dehumidification mode:
When the humidity ≥ Start humidity, relay conduction, green led on, dehumidification equipment begin to work;
When the humidity ≤ Shop humidity, relay disconnect, green led off, dehumidification equipment stops to work;
 
3. Humidificationmode:
When the humidity ≤ Start humidity, relay conduction, green led on, humidification equipment begin to work;
When the humidity ≥ Shop humidity, relay disconnect, green led off, humidification equipment stops to work;
 
4. Humidificationcorrection function RH (-10.0 ~ 10%):
The system is working for a long time and may be biased, through this function correctly, the actual humidity= measuring humidity + calibration value;

How to set the start/stop humidity:
 
1. In the running interface, Long Press ' RH+ ' key more than 3 seconds, into the start humidity settings interface, can be modified by RH+ RH- key, to be modified, waiting for 6s automatic exit and save;
2. In the running interface, Long Press ' RH-' key more than 3 seconds, into the stop humidity settings interface, can be modified by RH+ RH- key, to be modified after the parameters, waiting for 6s automatic exit and save;

Package includes:

1 x Module with Sensor




XY-WTH1-DC-6-30V-Temperature-and-Humidity-Controller-Module-Wet-Control-Switch-Constant-Sensor-Dual--1476976

XY-WTH1-DC-6-30V-Temperature-and-Humidity-Controller-Module-Wet-Control-Switch-Constant-Sensor-Dual--1476976

XY-WTH1-DC-6-30V-Temperature-and-Humidity-Controller-Module-Wet-Control-Switch-Constant-Sensor-Dual--1476976

XY-WTH1-DC-6-30V-Temperature-and-Humidity-Controller-Module-Wet-Control-Switch-Constant-Sensor-Dual--1476976

XY-WTH1-DC-6-30V-Temperature-and-Humidity-Controller-Module-Wet-Control-Switch-Constant-Sensor-Dual--1476976

XY-WTH1-DC-6-30V-Temperature-and-Humidity-Controller-Module-Wet-Control-Switch-Constant-Sensor-Dual--1476976

XY-WTH1-DC-6-30V-Temperature-and-Humidity-Controller-Module-Wet-Control-Switch-Constant-Sensor-Dual--1476976

Write a review

Note: HTML is not translated!
Bad Good

Shipping Time


After you successfully placed an order at RenhotecIC.com, you will receive a confirmation email with your invoice. Once your order is shipped, you will be emailed with the tracking information of your package. Also, you can choose your preferred shipping method during the checkout process. Kindly advise: please select DHL/FedEx if you need our product urgently.

The timeline of the whole shipping process is shown below:

img

The total delivery time is calculated from the time your order is successfully placed to the time received. Total delivery time is broken down into processing time and shipping time.

Processing time: The time it takes to prepare your item(s), includes preparing your items, performing quality inspections, and packaging for shipment. Normally, the processing time is 1-3 days (Only include Monday to Saturday ) after getting your order.

Shipping time: The time for your item(s) to travel from our warehouse to your destination. The shipping time depends on the shipping method you chose. Please refer to the shipping rate section for details. 


Shipping Rates


You could choose the shipping method based on your preference during checkout, different shipping methods will apply different rates and shipping times. Please check the following chart for detail:


Shipping MethodShipping RatesShipping Times
Flat Shipping (Promotion)
$10About 5-30 Working Days to Worldwide (Only include Monday to Saturday )

Standard Express(0.5KG starting price listed)

Based On WeightsAbout 5-15 Working Days to Worldwide (Only include Monday to Saturday )

Priority Express (0.5KG starting price listed)

Based On WeightsAbout 3-7 Working Days to Worldwide (Only include Monday to Saturday )

In addition, the transit time depends on where you're located, the shipping method you choose, and where your package comes from. We will keep you informed of any problems here to help you get your order as soon as possible. 

If you want to know more information, please contact the customer service by contact form or sales@renhotecic.com. We will settle your problem as soon as possible. Enjoy shopping!