Menu
Your Cart

XY-WT01 Digital Thermostat High Precision Digital Display Temperature Controller Refrigeration Heating

XY-WT01 Digital Thermostat High Precision Digital Display Temperature Controller Refrigeration Heating
XY-WT01 Digital Thermostat High Precision Digital Display Temperature Controller Refrigeration Heating
XY-WT01 Digital Thermostat High Precision Digital Display Temperature Controller Refrigeration Heating
XY-WT01 Digital Thermostat High Precision Digital Display Temperature Controller Refrigeration Heating
XY-WT01 Digital Thermostat High Precision Digital Display Temperature Controller Refrigeration Heating
XY-WT01 Digital Thermostat High Precision Digital Display Temperature Controller Refrigeration Heating
XY-WT01 Digital Thermostat High Precision Digital Display Temperature Controller Refrigeration Heating
$7.53
Ex Tax: $7.53
  • Stock: In Stock
  • Model: EB003210
  • SKU: EB003210

Product Function:

Set Temperature ---- SetT;
Backlash Temperature-----BackT;
1. Heating ModeH:
When Temperature ≤ SetT – BackT;Relay conduction, heating equipment begin to work;
WhenTemperature≥ SetT,Relaydisconnect, heating equipment stop work;
2. Refrigeration modeC:
When Temperature ≥ SetT+BackT;Relay conduction, refrigeration equipment begin to work;
When Temperature ≤ SetT;Relay conduction, refrigeration equipment stopwork;
3. High Temperature Alarm ’ALA:
When Temperature≥ AlarmTemperature,The system opens the sound and light alarm, and disconnects the relay, any key stops the sound light;
4. Delay Start‘OPH:
When a normal heating or refrigeration work is done, the system starts to time T, and only after the T≥OPH, the system can carry out the next round of heating or refrigeration work;
5. Temperature Correction FunctionOFE(-10.0 ~ 10.0℃):
The system will work for a long time and may have deviations that can be corrected by this function,Temperature = Measured + Calibration;
6. Parameter Remote Read/Set:
The parameters such as setting temperature, backlash temperature and temperature correction can be set through UART.
7. Real-time Temperature Report:
If the temperature reporting function is turned on, the product is transmitted to the terminal by the UART at 1s intervals, which facilitates data collection;
8. Relay enable (default enable):
If the relay is disable, the relay remains disconnected;
9. Restore factory Settings:
At the same time press the STOP, set key more than 3S, restore factory settings;


Working modesetting /backlash temperature :

1. In the running interface, short press SET key, enter the Quick setting interface;
2. After entering the Quick Setup interface, switch the parameters
3. Through theUP DOWN key, modify the parameter value, support short press/long press;
4. Long press SET to build more than 3S or continuous 6S without any key operation, exit quickly set the interface, and save parameters;

Alarm temperature/delay Start /temperature correction:

1. In the operating interface, long press SET more than 3s, enter the parameters to set the interface;
2. Enter the parameter to set the interface, through the short press SET key to switch to set the parameters;
3. through the UP DOWN key, modify the parameter value, support short press/long press;
4. Long press SET3s above or continuous 6S without any key operation, exit parameter set interface, and save parameters;

How to turn on high temperature alarm (default off):

Enter the parameter setting interface, switch to the alarm parameter ALA, turn on or off the high temperature alarm function by short pressing the STOP button, and if the high temperature alarm function closes, ALA displays '----' as a reminder;

How to turn on delay start (default 0ff):

Enter parameter setting interface, switch to alarm parameter OPH, turn on or off high temperature alarm function by short Press STOP button, if high temperature alarm function closes, OPH show '----' to remind;

Serial Control (MCU UART)

Communication standards:9600bps Data bits :8
Stop Bits :1
CRC :none
Flow control :none
 

CMD Description
start Start temperature report
stop Stop temperature report
read Read parameters setting
on Relay Enable
off Relay Disable
S:XXX Setting Temperature
-50 ~ -01
00.0~99.9
100~110
B:XX.X Set Backlash Temperature(00.0~30.0)
OFE:XX.X Temperature Calibration(-10.0 ~ 10.0)
ALA:XX.X Alarm Temperature(-50.0 ~ 110.0)
OPH:XXXX Delay Start(0 ~ 9999Minutes)
   
 
Package includes:

1 X XY-WT01 Controller

Details pictures:



XY-WT01-Digital-Thermostat-High-Precision-Digital-Display-Temperature-Controller-Refrigeration-Heati-1591868
XY-WT01-Digital-Thermostat-High-Precision-Digital-Display-Temperature-Controller-Refrigeration-Heati-1591868
XY-WT01-Digital-Thermostat-High-Precision-Digital-Display-Temperature-Controller-Refrigeration-Heati-1591868
XY-WT01-Digital-Thermostat-High-Precision-Digital-Display-Temperature-Controller-Refrigeration-Heati-1591868
XY-WT01-Digital-Thermostat-High-Precision-Digital-Display-Temperature-Controller-Refrigeration-Heati-1591868
XY-WT01-Digital-Thermostat-High-Precision-Digital-Display-Temperature-Controller-Refrigeration-Heati-1591868
XY-WT01-Digital-Thermostat-High-Precision-Digital-Display-Temperature-Controller-Refrigeration-Heati-1591868
XY-WT01-Digital-Thermostat-High-Precision-Digital-Display-Temperature-Controller-Refrigeration-Heati-1591868
XY-WT01-Digital-Thermostat-High-Precision-Digital-Display-Temperature-Controller-Refrigeration-Heati-1591868

Write a review

Note: HTML is not translated!
Bad Good

Shipping Time


After you successfully placed an order at RenhotecIC.com, you will receive a confirmation email with your invoice. Once your order is shipped, you will be emailed with the tracking information of your package. Also, you can choose your preferred shipping method during the checkout process. Kindly advise: please select DHL/FedEx if you need our product urgently.

The timeline of the whole shipping process is shown below:

img

The total delivery time is calculated from the time your order is successfully placed to the time received. Total delivery time is broken down into processing time and shipping time.

Processing time: The time it takes to prepare your item(s), includes preparing your items, performing quality inspections, and packaging for shipment. Normally, the processing time is 1-3 days (Only include Monday to Saturday ) after getting your order.

Shipping time: The time for your item(s) to travel from our warehouse to your destination. The shipping time depends on the shipping method you chose. Please refer to the shipping rate section for details. 


Shipping Rates


You could choose the shipping method based on your preference during checkout, different shipping methods will apply different rates and shipping times. Please check the following chart for detail:


Shipping MethodShipping RatesShipping Times
Flat Shipping (Promotion)
$10About 5-30 Working Days to Worldwide (Only include Monday to Saturday )

Standard Express(0.5KG starting price listed)

Based On WeightsAbout 5-15 Working Days to Worldwide (Only include Monday to Saturday )

Priority Express (0.5KG starting price listed)

Based On WeightsAbout 3-7 Working Days to Worldwide (Only include Monday to Saturday )

In addition, the transit time depends on where you're located, the shipping method you choose, and where your package comes from. We will keep you informed of any problems here to help you get your order as soon as possible. 

If you want to know more information, please contact the customer service by contact form or sales@renhotecic.com. We will settle your problem as soon as possible. Enjoy shopping!