Menu
Your Cart

Turbidity Meter Tester Digital Concentration Meter Monitor Measurement Range 0-200NTU

Turbidity Meter Tester Digital Concentration Meter Monitor Measurement Range 0-200NTU
Turbidity Meter Tester Digital Concentration Meter Monitor Measurement Range 0-200NTU
Turbidity Meter Tester Digital Concentration Meter Monitor Measurement Range 0-200NTU
Turbidity Meter Tester Digital Concentration Meter Monitor Measurement Range 0-200NTU
Turbidity Meter Tester Digital Concentration Meter Monitor Measurement Range 0-200NTU
Turbidity Meter Tester Digital Concentration Meter Monitor Measurement Range 0-200NTU
Turbidity Meter Tester Digital Concentration Meter Monitor Measurement Range 0-200NTU
Turbidity Meter Tester Digital Concentration Meter Monitor Measurement Range 0-200NTU
Turbidity Meter Tester Digital Concentration Meter Monitor Measurement Range 0-200NTU
$148.05
Ex Tax: $148.05
  • Stock: In Stock
  • Model: EB005825
  • SKU: EB005825
Features:

Microcomputer configuration, with an average measurement mode, with data storage and query functions, automatic switching range.
ZD series intelligent turbidimeter using light scattering principle, the calibration solution using formazine standard solution commonly used international. The utility model is a precise and intelligent instrument, which has the advantages of good linearity, accurate and reliable measurement and convenient operation.
Applicable to tap water pl ant, water treatment plant, swimming pool water reuse, the food and beverage industry as the instrument. It is a necessary instrument for water laboratory.
ZD seriesIntelligent turbidimeter using light scattering principle, the calibration solution using formazine standard solution commonly used international. The utility model is a precise and intelligent instrument, which has the advantages of good linearity, accurate and reliable measurement and convenient operation.
 
Specification:

Determination principle: 90° scattered light
Minimum display (NTU)0.1
Measurement range (NTU)0-200 / 0 ~1000
Calibration point0NTU,100NTU / 0NTU,50NTU,100NTU,200NTU,400NTU,800NTU,1000NTU
Indication error±8% (± 2.5%F.S)
Repeatability≤1%
Zero drift±1%F.S
Instrument weight0.5KG
Outline dimension210 x 75 x 70MM
Power supplyDC 1.5V x 5 AA alkaline dry cell / AC 220V/50Hz/DC7.5V/ 0.2A power adapter

Matters needing attention
 
ZDA series of scattered light turbidity meter is a precision measuring instrument which is combined with photoelectric. It is necessary to read the instruction manual carefully before operation and get accurate measurement results.
 
1, the use of the environment must meet the working conditions.
2, the measurement tank must be clean and dry for a long time, no dust, no need to cover the cover.
3, humid climate, must be extended to boot time.
4, the solution should be carefully poured into the sample bottle, to prevent the formation of bubbles, affecting the accuracy of measurement.
5, replace the sample bottle or after repair must be re calibration.
6, non professional maintenance engineer, do not open the instrument for maintenance.
 
Working conditions
 
1. The instrument should be placed in the drying room, use temperature of 5 DEG C - 35.
2. When used, should be placed on the flat surface, and avoid vibration.
3. Indoor lighting should not be too strong, and avoid direct sunlight irradiation.
4. Try to keep away from the high intensity magnetic field, electric field and high frequency electric equipment.
5. Avoid high temperature close to the instrument.
6. The power supply of the instrument: 220V± 22V, 50± 1Hz, and must have a good grounding wire.
 
Measurement preparation
 
1, open the instrument power switch;
2, do not fall wool soft cloth to wipe the water stain on the sample bottle and fingerprints, such as not easy to clean the cleaning agent can be soaked, and then rinse with water clean;
3, ready for school pocket zero turbidity water and preparing for the calibration of formazine turbidity standard solution
4, with a clean container to collect a representative sample;
 
Operation steps(see Appendix flow chart)
 
Measurement solutionturbidityThe instrument must be calibrated before.
 
1 Correction
 
Boot into the main interface menu window,“ switching ” key select “ correction ” option.At this time the instrument display into0000NTU turbidity liquid, open the machine above the sliding cover panel,Will be installedYesZero turbidity waterSample bottleMeasurement pool,Cover with sliding coverTo be stabilized by “ confirm ” key. In order to put in the correct solution. Press “ confirm ” key end. Enter the main menu option. Or press “ switch ” key forced exit, exit to save the corrected data. Enter the main menu interface.
 
Note: every time to wipe cleanSample bottle wallTraces of water and fingerprints,Should not leave any traces, so as not to affect the measurement accuracy. every timeSample bottleThe direction and the position of the measuring pool are as consistent as possible.Please use the same sample bottle when comparing and measuring, so as to reduce the inaccuracy of the data value caused by the error of the sample bottle.
 
2,turbidity measure
 
Main interface menu window,By “ switch ” key select “ measure ” option.
Will be measuredsamplePour cleanSample bottleIn, will be installedYesTo be measuredsampleSample bottleMeasurement pool,Cover with sliding cover,The numerical display is the instrument to be checked.Turbidity value.
 
3,ProtectDeposit,extractUsage method
 
In the measurement process, the measurement can be carried outPreservation. Press“ save ”Key can be stored up to10 sets of data. Sign outPreservationPress“confirm”Key, back to the status of the measurement.
 
PreservationData can be queried. Press“ extraction ”Key can. Sign outextractPress“confirm”Key, back to the status of the measurement.
 
Package included:

1 x Digital Concentration Meter
 
Details pictures:



Turbidity-Meter-Tester-Digital-Concentration-Meter-Monitor-Measurement-Range-0-200NTU-1449906

Turbidity-Meter-Tester-Digital-Concentration-Meter-Monitor-Measurement-Range-0-200NTU-1449906

Turbidity-Meter-Tester-Digital-Concentration-Meter-Monitor-Measurement-Range-0-200NTU-1449906

Turbidity-Meter-Tester-Digital-Concentration-Meter-Monitor-Measurement-Range-0-200NTU-1449906

Write a review

Note: HTML is not translated!
Bad Good

Shipping Time


After you successfully placed an order at RenhotecIC.com, you will receive a confirmation email with your invoice. Once your order is shipped, you will be emailed with the tracking information of your package. Also, you can choose your preferred shipping method during the checkout process. Kindly advise: please select DHL/FedEx if you need our product urgently.

The timeline of the whole shipping process is shown below:

img

The total delivery time is calculated from the time your order is successfully placed to the time received. Total delivery time is broken down into processing time and shipping time.

Processing time: The time it takes to prepare your item(s), includes preparing your items, performing quality inspections, and packaging for shipment. Normally, the processing time is 1-3 days (Only include Monday to Saturday ) after getting your order.

Shipping time: The time for your item(s) to travel from our warehouse to your destination. The shipping time depends on the shipping method you chose. Please refer to the shipping rate section for details. 


Shipping Rates


You could choose the shipping method based on your preference during checkout, different shipping methods will apply different rates and shipping times. Please check the following chart for detail:


Shipping MethodShipping RatesShipping Times
Flat Shipping (Promotion)
$10About 5-30 Working Days to Worldwide (Only include Monday to Saturday )

Standard Express(0.5KG starting price listed)

Based On WeightsAbout 5-15 Working Days to Worldwide (Only include Monday to Saturday )

Priority Express (0.5KG starting price listed)

Based On WeightsAbout 3-7 Working Days to Worldwide (Only include Monday to Saturday )

In addition, the transit time depends on where you're located, the shipping method you choose, and where your package comes from. We will keep you informed of any problems here to help you get your order as soon as possible. 

If you want to know more information, please contact the customer service by contact form or sales@renhotecic.com. We will settle your problem as soon as possible. Enjoy shopping!

Tags: Monitor