Menu
Your Cart

DC 120v 100A 200A 500A LCD Combo Meter Voltage Current KWh Watt Meter 12v 24v 48v 96V Battery Capacity Power monitoring 1.8inch Color Screen

DC 120v 100A 200A 500A LCD Combo Meter Voltage Current KWh Watt Meter 12v 24v 48v 96V Battery Capacity Power monitoring 1.8inch Color Screen
DC 120v 100A 200A 500A LCD Combo Meter Voltage Current KWh Watt Meter 12v 24v 48v 96V Battery Capacity Power monitoring 1.8inch Color Screen
DC 120v 100A 200A 500A LCD Combo Meter Voltage Current KWh Watt Meter 12v 24v 48v 96V Battery Capacity Power monitoring 1.8inch Color Screen
DC 120v 100A 200A 500A LCD Combo Meter Voltage Current KWh Watt Meter 12v 24v 48v 96V Battery Capacity Power monitoring 1.8inch Color Screen
DC 120v 100A 200A 500A LCD Combo Meter Voltage Current KWh Watt Meter 12v 24v 48v 96V Battery Capacity Power monitoring 1.8inch Color Screen
DC 120v 100A 200A 500A LCD Combo Meter Voltage Current KWh Watt Meter 12v 24v 48v 96V Battery Capacity Power monitoring 1.8inch Color Screen
DC 120v 100A 200A 500A LCD Combo Meter Voltage Current KWh Watt Meter 12v 24v 48v 96V Battery Capacity Power monitoring 1.8inch Color Screen
DC 120v 100A 200A 500A LCD Combo Meter Voltage Current KWh Watt Meter 12v 24v 48v 96V Battery Capacity Power monitoring 1.8inch Color Screen
DC 120v 100A 200A 500A LCD Combo Meter Voltage Current KWh Watt Meter 12v 24v 48v 96V Battery Capacity Power monitoring 1.8inch Color Screen
DC 120v 100A 200A 500A LCD Combo Meter Voltage Current KWh Watt Meter 12v 24v 48v 96V Battery Capacity Power monitoring 1.8inch Color Screen
DC 120v 100A 200A 500A LCD Combo Meter Voltage Current KWh Watt Meter 12v 24v 48v 96V Battery Capacity Power monitoring 1.8inch Color Screen
$28.61
Ex Tax: $28.61
  • Stock: In Stock
  • Model: EB003055
  • SKU: EB003055

Available Options

Descriptions:
 
It is a basic multi-function instrument that can display various physical parameters such as voltage, current, power, capacity, energy, and operating time in real time. Overvoltage, undervoltage, overcurrent can be achieved through reserved relay interfaces. . And the meter uses 1.8-inch color LCD as a display, display data more comprehensive, clear and easy to observe. This meter is ideal for applications that require monitoring of the output voltage and current as well as applications such as charging and discharging batteries.
 
Features:
 
1. The bidirectional detection current makes it easy for the user who detects the charge and discharge to detect the bidirectional current without changing the wiring direction.
2. Power off memory function, able to memorize the number of AH and WH before power off after power off, which is convenient for observation and measurement.
3, time and AH number clear function, does not affect the next measurement.
4. The number of AHs can be filled up without affecting the direct discharge measurement.
5, voltage, current, charge capacity AH number, WH number, time, power at the same time display, display information is comprehensive and clear.
6, with output off function keys, flexible open or shut off the output.
7, with over-voltage, over-current protection.
8, when necessary, you can turn off the LCD display, reduce product power
 
Notice:Default without Temperature measurement function

Specifications:


DC-120v-100A-200A-500A-LCD-Combo-Meter-Voltage-Current-KWh-Watt-Meter-12v-24v-48v-96V-Battery-Capaci-1543892

Package Includes:
 
1 x Voltmeter

 
Instructions
 
1. AH, WH display switch, click to switch to display WH number, click to switch to display AH number.
2. Press OK key to enter the system parameter setting interface, then press OK key to switch the type of setting parameter. The set parameters include BAT, BPC, OPP, OVP, LVP, NCP, OCP, OTP, ADS, TTL, CLR, DTE. , Click to change the parameters, after the parameters are set, press OK to exit the parameter setting interface.
 
Third, function introduction
 
1, "BAT" battery capacity value setting, this parameter is to set the battery measured total capacity.
2, "BPC" battery remaining capacity percentage, can be set according to the value of the remaining battery AH
 
4, "OVP" set over-voltage protection value, if the OVP value is set, when the actual measured voltage value is greater than the set value, it will prompt over-voltage, and cut off the relay (self-provisioned).
5, "LVP" set over-voltage protection value, if you set the LVP value, when the actual measured voltage value is less than the set value, it will prompt undervoltage, and cut off the relay (self-provisioned).
6, "NCP" set over-voltage protection value, if the NCP value is set, when the actual measurement of the charging current value is less than the set value, it will prompt over-current, and cut off the relay (self-provisioned).
7, "OCP" set over-voltage protection value, if the OCP value is set, when the actual measurement of discharge current value is less than the set value, it will prompt over-current, and cut off the relay (self-provisioned).
8, "OTP" set over-temperature protection value, if the OTP value is set, when the actual measured temperature value is greater than the set value, it will prompt the temperature, and cut off the relay (self-provisioned ,Default without Temperature measurement function).
9, "ADS" communication address code settings. In multi-machine communication, multi-machine communication is achieved by setting the address code.
10, "TTL" instrument default relay output power state, normally open or normally closed.
11, "CLR" no-load current clear function, if the actual no-load current is zero

Connection mode
 
(1) its own power supply wiring diagram
DC-120v-100A-200A-500A-LCD-Combo-Meter-Voltage-Current-KWh-Watt-Meter-12v-24v-48v-96V-Battery-Capaci-1543892

Note: If the voltage range of the tested battery (power supply) is between (6-75V) during the normal operation, it can use its own power supply wiring mode. First, adjust the jumper cap of the power supply selection interface to “2W”, and then connect it. The positive pole of the battery (power supply) is connected to the voltage measurement port “Bat+”, and the negative pole of the battery (power supply) is connected to the shunt “BAT-”. The positive and negative poles of the power supply should not be connected wrongly or reversed. Connect the positive pole of the battery (power supply) to the positive pole of the load, and connect the negative pole of the battery (power supply) to the negative pole of the load through the other end of the shunt; the positive pole of the charger is connected to the positive pole of the battery, and the negative pole of the charger passes through the shunt. One end is connected to the battery (power supply).

(2) External power supply wiring diagram

DC-120v-100A-200A-500A-LCD-Combo-Meter-Voltage-Current-KWh-Watt-Meter-12v-24v-48v-96V-Battery-Capaci-1543892

Note: If the voltage range of the tested battery (power supply) during normal operation is not between (6-75V), the external power supply connection mode can be used. The external power supply voltage range is (6-75)V. The power supply selection interface jumper cap is firstly used. Adjust to "3W", then connect the positive terminal of the battery (power supply) to the voltage measurement port "Bat+" at the time of connection, connect the negative pole of the battery (power supply) to the shunt "BAT-", and the positive and negative poles of the power supply should not be connected. Wrong or reversed. Connect the positive pole of the battery (power supply) to the positive pole of the load, and connect the negative pole of the battery (power supply) to the negative pole of the load through the other end of the shunt; the positive pole of the charger is connected to the positive pole of the battery, and the negative pole of the charger passes through the shunt. One end is connected to the negative pole of the battery (power supply) phase.

(3) Electrical relay wiring instructions
DC-120v-100A-200A-500A-LCD-Combo-Meter-Voltage-Current-KWh-Watt-Meter-12v-24v-48v-96V-Battery-Capaci-1543892

Note: The relay's working power is provided by an external power supply. If the relay is connected, an external power supply with the same working voltage as the relay must be provided, and the power supply status of the instrument is adjusted to the “3W” state. Connect the control port of the relay to the interface of the controller, and then connect the negative pole of the power supply to the “BAT-” position of the shunt through the normally open or normally closed port of the relay, and the wiring of other parts will not change.

 
Details Pictures:
 



DC-120v-100A-200A-500A-LCD-Combo-Meter-Voltage-Current-KWh-Watt-Meter-12v-24v-48v-96V-Battery-Capaci-1543892

DC-120v-100A-200A-500A-LCD-Combo-Meter-Voltage-Current-KWh-Watt-Meter-12v-24v-48v-96V-Battery-Capaci-1543892

DC-120v-100A-200A-500A-LCD-Combo-Meter-Voltage-Current-KWh-Watt-Meter-12v-24v-48v-96V-Battery-Capaci-1543892

DC-120v-100A-200A-500A-LCD-Combo-Meter-Voltage-Current-KWh-Watt-Meter-12v-24v-48v-96V-Battery-Capaci-1543892

DC-120v-100A-200A-500A-LCD-Combo-Meter-Voltage-Current-KWh-Watt-Meter-12v-24v-48v-96V-Battery-Capaci-1543892

Write a review

Note: HTML is not translated!
Bad Good

Shipping Time


After you successfully placed an order at RenhotecIC.com, you will receive a confirmation email with your invoice. Once your order is shipped, you will be emailed with the tracking information of your package. Also, you can choose your preferred shipping method during the checkout process. Kindly advise: please select DHL/FedEx if you need our product urgently.

The timeline of the whole shipping process is shown below:

img

The total delivery time is calculated from the time your order is successfully placed to the time received. Total delivery time is broken down into processing time and shipping time.

Processing time: The time it takes to prepare your item(s), includes preparing your items, performing quality inspections, and packaging for shipment. Normally, the processing time is 1-3 days (Only include Monday to Saturday ) after getting your order.

Shipping time: The time for your item(s) to travel from our warehouse to your destination. The shipping time depends on the shipping method you chose. Please refer to the shipping rate section for details. 


Shipping Rates


You could choose the shipping method based on your preference during checkout, different shipping methods will apply different rates and shipping times. Please check the following chart for detail:


Shipping MethodShipping RatesShipping Times
Flat Shipping (Promotion)
$10About 5-30 Working Days to Worldwide (Only include Monday to Saturday )

Standard Express(0.5KG starting price listed)

Based On WeightsAbout 5-15 Working Days to Worldwide (Only include Monday to Saturday )

Priority Express (0.5KG starting price listed)

Based On WeightsAbout 3-7 Working Days to Worldwide (Only include Monday to Saturday )

In addition, the transit time depends on where you're located, the shipping method you choose, and where your package comes from. We will keep you informed of any problems here to help you get your order as soon as possible. 

If you want to know more information, please contact the customer service by contact form or sales@renhotecic.com. We will settle your problem as soon as possible. Enjoy shopping!