Menu
Your Cart

DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s

DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s
DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s
DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s
DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s
DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s
DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s
DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s
DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s
DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s
DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s
DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s
$249.99
Ex Tax: $249.99
  • Stock: In Stock
  • Model: EB004532
  • SKU: EB004532

Description:
 
Hantek DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s
 
Features: 
 
100MHz bandwidths
1GSa/s Real Time sample rate
Large (7.0-inch) color display,WVGA(800x480)
R'ecord length up to 40'K
Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.
USB host and device connectivity, standard
Multiple automatic measurements
Four math functions, including FFTs standard
Provides software for PC real-time analysis 
 
Specification:
 
 
Model DSO5202P DSO5102P DSO5072P
Acquisition
Sample Rate  Real-Time Sample: 1GS/s
Equivalent Sample: 25GS/s
Acquisition Modes      
Normal Normal data only
Pea'k Detect High-frequency and randon glith capture
Average Wavefom Average, selectable 4,8,16,32,64,128
Inputs
Inputs Coupling AC, DC, GND
Inpits Impendance 1MΩ±2% II20pF±3pF
Probe Attenuation 1X, 10X
Supported Probe Attenuation Factor 1X, 10X, 100X, 1000X
Maximum Input Voltage CAT I and CAT II: 300VRMS (10×), Installation Category;
CAT III: 150VRMS (1×);
Installation Category II: derate at 20dB/decade above 100kHz to 13V Pea'k AC at 3MHz* and above. 
For non-sinusoidal waveforms, Pea'k value must be less than 450V. 
Excursion above 300V should be of less than 100ms duration. 
RMS signal level including all DC components removed through AC coupling must be limited to 300V.
 If these values are exceeded, damage to the oscilloscope may occur.
Horizontal
Sample Rate Range 500MS/s--1GS/s
Waveform Interpolation (sin x)/x
R'ecord Length 40'K
SEC/DIV Range 4ns/div to 40s/div 4ns/div to 40s/div
Sample Rate and
Delay Time Accuracy
±50ppm(at over any ≥1ms time interval)
Position Range 2ns/div to 10ns/div; 
(-4div x s/div) to 20ms;
20ns/div to 80us/div; (-8div x s/div) to 40ms;
200us/div to 40s/div; (-8div x s/div) to 400s
Incremental  Time Measurement Accuracy 
(Full Bandwidth)
Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);
>16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);
Sample interval = s/div ÷ 200
Vertical
Vertical Resolution 8-bit resolution, all channel sampled simultaneously
Position Range 2mV/div to 200mV/div, ±2V
200mV/div to 5V/div, ±50V
Bandwidth 100MHz 100MHz 70MHz
Rise Time at BNC( typical) 3.5ns  3.5ns 5ns
Analog Bandwidth in Normal and
 Average modes at BNC or with probe, DC Coupled
2mV/div to 20mV/div, ±400mV;  50mV/div to 200mV/div, ±2V
500mV/div to 2V/div, ±40V; 5V/div, ±50V
Math +, -, *, /, FFT
FFT Windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman;
1024 sample point
Bandwidth Limit 20MHz
Low Frequency Response (-3db) ≤10Hz at BNC
DC Gain Accuracy ±3% for Normal or Average acquisition mode, 5V/div to 10mV/div;
±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div
DC Measurement Accuracy, 
Average Acquisition Mode
When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected; 
When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; 
Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/div
Volts Measurement Repeatability, 
Average Acquisition Mode
D1elta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions
Trigger System
Trigger Types Edge, Video, Pulse, Slope, Over time, Alternative
Trigger Source CH1, CH2, EXT, EXT/5, AC Line
Trigger Modes Auto, Normal, Single
Coupling Type DC, AC, Noise Reject, HF Reject, LF Reject
Trigger Sensitivity
(Edge Trigger Type)
DC(CH1,CH2):
1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;
DC(EXT): 
200mV from DC to 100MHz; 350mV from 100MHz to 200MHz;
DC(EXT/5):       
1V from DC to 100MHz;1.75V from 100MHz to 200MHz;       
AC: Attenuates signals below 10Hz;
HF Reject: Attenuates signals above 80kHz; 
LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz
Trigger Level Range CH1/CH2: ±8 divisions from center of screen; 
EXT: ±1.2V;
EXT/5:±6V
Trigger Level Accuracy( typical)Accuracy 
is for signals having rise and fall times ≥20ns
CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen;
EXT: ± (6% of setting + 40mV);
EXT/5: ± (6% of setting + 200mV);
Set Level to 50%(typical) Operates with input signals ≥50Hz
Video Trigger  
Video Trigger Type  CH1, CH2: Pea'k-to-Pea'k amplitude of 2 divisions;
EXT: 400mV;
EXT/5: 2V
Signal Formats and Field Rates, Video Trigger Type Supports NTSC, PAL and SECAM broadcast systems for any field or any line
Holdoff Range 100ns ~ 10s
Pulse Width Trigger  
Pulse Width Trigger Mode Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse
Pulse Width Trigger Point Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.
Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge.
Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.
Less than: The trigger point is the trailing edge.
Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width
Pulse Width Range 20ns ~ 10s
Slope Trigger  
Slope Trigger Mode Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope
Slope Trigger Point Equal: The oscilloscope triggers when the waveform slope is equal to the set slope.
Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.
Less than: The oscilloscope triggers when the waveform slope is less than the set slope.
Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.
Time Range 20ns ~ 10s
Overtime Trigger  
Over Time Mode Rising edge or Falling edge
Time Range 20ns ~ 10s
Alternative Trigger  
Trigger on CH1 Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger on CH2 Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger Frequency Counter
Readout Resolution 6 digits
Accuracy (typical) ±30ppm (including all frequency reference errors and ±1 count errors)
Frequency Range AC coupled, from 4Hz Min to rated bandwidth
Signal Source Pulse Width or Edge Trigger modes: all available trigger sources
The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses 
due to changes in the run status, or acquisition of a single shot event has completed.
Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, 
such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time.
Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.
Video Trigger mode: The Frequency Counter does not work.
Measure
Cursor Measurement Voltage difference between cursors: ΔV
Time difference between cursors: ΔT
Reciprocal of ΔT in Hertz (1/ΔT)
Auto Measuerment Frequency, Period, Mean, Pk-Pk, Cycli RMS, Min, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH, FRF, FFR, LRR, LRF, LFR, LFF
Display
Display Type 7 inch 64K color TFT (diagonal liquid crystal)
Display Resolution 800 horizontal by 480 vertical pixels
Display Contrast Adjustable (16 gears) with the progress bar
Probe Compensator Output
Output Voltage( typical) About 5Vpp into ≥1MΩ load
Frequency(typical) 1kHz
Power Supply
Supply Voltage 100-120VACRMS(±10%), 45Hz to 440Hz, CATII
120-240VACRMS(±10%), 45Hz to 66Hz, CATII
Power Consumption <30W
Fuse 2A, T rating, 250V
Environmental
Temperature Operating: 32F to 122F (0C to 50C);
Nonoperating: -40F to 159.8F (-40C to +71C)
Cooling Method Convection
Humidity +104F or below (+40C or below): ≤90% relative humidity;
106F to 122F (+41C to 50C): ≤60% relative humidity
Altitude Operating: Below 3,000m (10,000 feet);
Nonoperaring: Below 15,000m(50,000 feet)
Mechanical
Size Length 385mm, Width 200mm, Height 245mm
Weight 3.5KG(with Packing);  2.08KG(without Packing)

Package includes: 
 
1 x Digital Storage Oscilloscope
2 x Probes (PP150)
1 x Oscilloscope Power Cable
1 x Hantek data CD
1 x USB line
1 x Manufacturer Certificate


Good News!

MUSTOOL MDS2112P Ultra-thin Dual Channel Digital Storage Oscilloscope
100MHz Bandwidth 1GS/s Sampling Rate + Automatic Waveform Measurement
>>>
Hantek-DSO5102P-USB-Digital-Storage-Oscilloscope-2Channels-100MHz-1GSas-1013032
 
Details pictures: 


 
 

 
 
 
 
 
 

Hantek-DSO5102P-USB-Digital-Storage-Oscilloscope-2Channels-100MHz-1GSas-1013032,Hantek-DSO5102P-USB-Digital-Storage-Oscilloscope-2Channels-100MHz-1GSas-1013032,Hantek-DSO5102P-USB-Digital-Storage-Oscilloscope-2Channels-100MHz-1GSas-1013032,Hantek-DSO5102P-USB-Digital-Storage-Oscilloscope-2Channels-100MHz-1GSas-1013032,Hantek-DSO5102P-USB-Digital-Storage-Oscilloscope-2Channels-100MHz-1GSas-1013032

Write a review

Note: HTML is not translated!
Bad Good

Shipping Time


After you successfully placed an order at RenhotecIC.com, you will receive a confirmation email with your invoice. Once your order is shipped, you will be emailed with the tracking information of your package. Also, you can choose your preferred shipping method during the checkout process. Kindly advise: please select DHL/FedEx if you need our product urgently.

The timeline of the whole shipping process is shown below:

img

The total delivery time is calculated from the time your order is successfully placed to the time received. Total delivery time is broken down into processing time and shipping time.

Processing time: The time it takes to prepare your item(s), includes preparing your items, performing quality inspections, and packaging for shipment. Normally, the processing time is 1-3 days (Only include Monday to Saturday ) after getting your order.

Shipping time: The time for your item(s) to travel from our warehouse to your destination. The shipping time depends on the shipping method you chose. Please refer to the shipping rate section for details. 


Shipping Rates


You could choose the shipping method based on your preference during checkout, different shipping methods will apply different rates and shipping times. Please check the following chart for detail:


Shipping MethodShipping RatesShipping Times
Flat Shipping (Promotion)
$10About 5-30 Working Days to Worldwide (Only include Monday to Saturday )

Standard Express(0.5KG starting price listed)

Based On WeightsAbout 5-15 Working Days to Worldwide (Only include Monday to Saturday )

Priority Express (0.5KG starting price listed)

Based On WeightsAbout 3-7 Working Days to Worldwide (Only include Monday to Saturday )

In addition, the transit time depends on where you're located, the shipping method you choose, and where your package comes from. We will keep you informed of any problems here to help you get your order as soon as possible. 

If you want to know more information, please contact the customer service by contact form or sales@renhotecic.com. We will settle your problem as soon as possible. Enjoy shopping!