Menu
Your Cart

3pcs XH-W1302 High Precision Digital Temperature Controller Special For 12V Input 12V Output Semiconductor Refrigeration Chip

3pcs XH-W1302 High Precision Digital Temperature Controller Special For 12V Input 12V Output Semiconductor Refrigeration Chip
3pcs XH-W1302 High Precision Digital Temperature Controller Special For 12V Input 12V Output Semiconductor Refrigeration Chip
3pcs XH-W1302 High Precision Digital Temperature Controller Special For 12V Input 12V Output Semiconductor Refrigeration Chip
3pcs XH-W1302 High Precision Digital Temperature Controller Special For 12V Input 12V Output Semiconductor Refrigeration Chip
3pcs XH-W1302 High Precision Digital Temperature Controller Special For 12V Input 12V Output Semiconductor Refrigeration Chip
3pcs XH-W1302 High Precision Digital Temperature Controller Special For 12V Input 12V Output Semiconductor Refrigeration Chip
3pcs XH-W1302 High Precision Digital Temperature Controller Special For 12V Input 12V Output Semiconductor Refrigeration Chip
3pcs XH-W1302 High Precision Digital Temperature Controller Special For 12V Input 12V Output Semiconductor Refrigeration Chip
3pcs XH-W1302 High Precision Digital Temperature Controller Special For 12V Input 12V Output Semiconductor Refrigeration Chip
3pcs XH-W1302 High Precision Digital Temperature Controller Special For 12V Input 12V Output Semiconductor Refrigeration Chip
3pcs XH-W1302 High Precision Digital Temperature Controller Special For 12V Input 12V Output Semiconductor Refrigeration Chip
3pcs XH-W1302 High Precision Digital Temperature Controller Special For 12V Input 12V Output Semiconductor Refrigeration Chip
3pcs XH-W1302 High Precision Digital Temperature Controller Special For 12V Input 12V Output Semiconductor Refrigeration Chip
$25.99
Ex Tax: $25.99
  • Stock: In Stock
  • Model: EB0043211
  • SKU: EB0043211
Features:
 
High-speed flash RAM processing chip
Power-off setting automatic memory
Control accuracy 0.1 degrees Celsius
Button buzzer (can be turned off)
High temperature buzzer alarm (0-110 degrees free setting)
Set the hysteresis of 0.5, control the decimal (0.5-15.0)
 
Technical parameter:
 
Temperature control range: -50~110°C
Resolution: -9.9~99.9 when 0.1 °C Other temperature range 1 °C
Temperature measurement accuracy: 0.1 °C
Control accuracy: 0.1 °C
Hysteresis accuracy: 0.1 °C
Refresh rate: 0.5 S
Input power: DC/AC 12V
Measurement input: NTC (10K 0.5%) waterproof sensor
Output: 1 relay output, capacity = 10A
Environmental requirements: -10~60°C Humidity 20%-85%
Specification size: 78*51mm (mounting hole M3. diagonal 75mm)
Power consumption of the whole machine: quiescent current: ≤35MA Pull-in current: ≤65MA

Package includes:

3 x XH-W1302 High Precision Digital Temperature Controller


Instructions:
 
Connect the power supply and equipment to supply power to the controller. At this time, it is displayed as measuring temperature. Press SET once, the display temperature will flash, press +- to set the desired temperature (press +- to quickly raise and lower) After finishing, press SET to confirm the return. At this time, the controller automatically performs relay on/off according to the setting! The output of the thermostat is a 10A relay, which satisfies various high-power loads, and connects the control circuit to supply power to the thermostat. At this time, the display shows the ambient temperature.
Fourth, the indicator light, digital tube and buzzer status description
Indicator light: Blinking indicates cooling or heating start delay, always on indicates that the relay is closed
Digital tube: Display LL is the sensor open circuit, please follow the instructions to connect the sensor; display HH is out of the measurement range, the thermostat will force the relay to be disconnected; display --- for high temperature alarm
Buzzer: When the digital tube displays LL, HH or ---, the buzzer emits a di-di-di -beep
 
Parameter function description:

Code Code description Set range Factory setting
P0 Cooling/heating C/H C
P1 Backlash setting 0.5-15 2
P2 Maximum setting limit 110 110
P3 Minimum setting lower limit -50 -50
P4 Temperature correction  -7~7°C 0
P5 Delayed start time 0-10 min 0
P6 Buzzer switch ON/OFF ON
P7 High temperature alarm 0-110° OFF
P8 Reset ON/OFF OFF
 
Press and hold SET for 5 seconds to enter the main menu settings, press +- to switch P0...P8 long press SET or 10 seconds without button action controller automatically confirm return
 
P0: cooling and heating mode
 
Press and hold SET for 5 seconds to display P0, press SET once to set the working mode, press +- to switch [H is heating mode] [C is cooling mode] Press SET once to return, long press SET or 10 seconds without button action controller automatically confirm carry out
In the cooling mode: when the temperature measurement value ≥ temperature set point, the refrigeration relay is closed, the refrigerator starts; when the temperature measurement value ≤ temperature set point - the return difference, the refrigeration relay is disconnected, the refrigerator is closed
In the heating mode: when the temperature measurement value ≤ temperature set point, the heating relay pulls in and the heater starts; when the temperature measurement value ≥ temperature set point + hysteresis, the heating relay is turned off and the heater is turned off.
 
P1: Difference setting
 
Press and hold SET for 5 seconds to display P0, press +- to switch to P1, press SET once to return the difference, press +- to set the difference to 0.5-15, press SET once when finished, long press SET or 10 seconds without button Motion controller automatically confirms completion
In the cooling mode: when the temperature measurement value ≥ the set value, the relay is closed, the refrigerator starts; when the temperature measurement value ≤ the set value - the difference value, the relay is turned off and the refrigerator is turned off.
For example, the environment is 30 °C, the set value is 25 °C, and the hysteresis is set to 2 °C. After the power is turned on, the relay closes the refrigerator to start. When the cooling reaches 23 °C, the relay turns off the refrigerator and the refrigerator is turned off. The opening temperature starts to rise. When it rises to the set value of 25 °C, the relay closes the refrigerator to start again, so the repeated cycle control temperature is not higher than 25 °C.
In the heating mode: when the temperature measurement value ≤ the set value, the relay is closed, the heater is started; when the temperature measurement value ≥ the set value + the return value, the relay is turned off and the heater is turned off.
For example, if the environment is 10 °C, the set value is 25 °C, and the hysteresis is set to 2 °C. After the power is turned on, the relay closes the heater to start. When it is heated to 27 °C, the relay turns off the heater, and the heater is turned off. The opening temperature begins to decrease. When it drops to the set value of 25 °C, the relay closes the heater again, so the repeated cycle control temperature is not lower than 25 °C.

P2 maximum temperature setting upper limit:
 
In order to avoid the danger of setting the temperature too high due to the misoperation of others, the temperature controller has the highest setting upper limit function, which limits the setting range of the highest temperature setting point controlled by the thermostat.
Press and hold SET for 5 seconds to display P0, press +- to switch to P2, press SET once to set the upper limit, press +- to set the highest settable temperature, the maximum value is 110, press SET once after completion, press SET or 10 Second no button action controller automatically confirms completion
For example: set to 60 temperature set point can only be set to 60 ° C. If the temperature set point is to be expanded, the upper limit set value needs to be adjusted first.

P3 lowest temperature setting lower limit:
 
In order to avoid the ice blockage caused by the misoperation of others, the temperature controller has the lowest setting upper and lower limit functions, which limits the setting range of the lowest temperature set point controlled by the thermostat.
Press and hold SET for 5 seconds to display P0, press +- to switch to P3, press SET once to set the minimum lower limit, press +- to set the lowest settable temperature, the lowest value is -50, press SET once after completion, press SET or 10 seconds without button action controller automatically confirms completion
For example: set to 2 temperature set point can only be set to 2 °C minimum. If the temperature set point is to be expanded at a lower temperature range, you need to adjust the lower limit set value first.

P4 temperature correction
 
When the measured temperature is deviated from the standard temperature or due to special needs of the user's hardware, this function can be used for correction. The corrected temperature = temperature before correction + correction value The valid range is -7.0~7.0
Press and hold SET for 5 seconds to display P0, press +- to switch to P4, press SET once to correct, press +- to set the correction value, press SET once after completion, long press SET or 10 seconds without button action controller automatically confirms completion
For example, the normal display is 25 degrees; when the temperature is corrected to 0, it displays 25 degrees; when the temperature is corrected to 1.5, it shows 26.5 degrees; when the temperature is corrected to -1.5, it shows 23.5;

P5 Delay start time Unit: minute
 
When the refrigerator or heater is working with a delay, the delay function can be turned on to protect the life of the device.
Press and hold SET for 5 seconds to display P0, press +- to switch to P5, press SET once to set the delay start time unit is minute, press +- to set 0-10 minutes, press SET once after completion, press SET for 10 seconds No button action controller automatically confirms completion
In the cooling mode: the first time the power is turned on, if the current temperature ≥ the set value, the refrigerator will not start the cooling immediately, and it needs to run after the set delay time.
In the heating mode: the first time the power is turned on, if the current temperature ≤ the set value, the heater will not start the heating immediately, and it needs to run after the set delay time.
The chiller starts immediately when the downtime between the two starts of the chiller or heater is greater than the set value of the delay start time;
When the stop interval between the two starts of the refrigerator or heater is less than the set value of the delay start time, the device can start after restarting the set delay time of the set after the run. The delay time is calculated from the moment of shutdown.
For example, the setting delay is 5 minutes in the cooling state, the cooling device starts to delay after the power is turned on, and the refrigerator is turned on after 5 minutes. When the required temperature is reached, the refrigerator stops, and the timing starts, when the next cooling start timing is completed. Work, unfinished time to wait for the end of the time to work, the LED indicator flashes during the delay
When the delay start is set to 0, it is equal to the off delay function.

P6 button tone switch
 
Press and hold SET for 5 seconds to display P0, press +- to switch to P6, press SET once to set whether to enable button sound, press +- to set on/off, press SET once after completion, long press SET or 10 seconds without button action control Automatic confirmation is completed
When the buzzer switch is set to on/off, the button will sound when the button is activated, and the buzzer will be turned off when the button is set to off.

P7 high temperature alarm
 
Press and hold SET for 5 seconds to display P0, press +- to switch to P7, press SET once to display on/off (set to off to turn off secondary function). Set to on and press SET once to set high temperature alarm temperature point, press +- to set 0 ~110, press SET once after completion, long press SET or 10 seconds without button action controller automatically confirms completion
The high temperature alarm setting range is 0-110 or off for the secondary function. After reaching the high temperature alarm, the buzzer will make a rapid drip sound and force the relay to be disconnected.
For example, we need to warm a liquid or space to 40 degrees, set 80 degrees as a dangerous temperature, and start the high temperature alarm relay to disconnect the buzzer when the temperature is higher than 80 degrees due to external irresistible factors. Alarm, promptly remind the staff to take corresponding measures to recover the loss! The alarm temperature can be set according to actual needs. If you do not want this function, you can set the temperature to off. Note that when the normal temperature is restored, the high temperature alarm thermostat is automatically released.

P8 Factory reset
 
Due to some human reasons, the internal setting of the thermostat is confusing. It takes a lot of time to set the item. In this case, you can use this function to restore the factory settings. The specific method is
Press and hold SET for 5 seconds to display P0, press +- to switch to P8, press SET once to set to on or off, on to restore factory settings, off to not perform any action, press SET to return after completion, long press SET or 10 seconds The clock no button action controller automatically restores the factory settings parameters as shown in the table below.
 





3pcs-XH-W1302-High-Precision-Digital-Temperature-Controller-Special-For-12V-Input-12V-Output-Semicon-1637873

3pcs-XH-W1302-High-Precision-Digital-Temperature-Controller-Special-For-12V-Input-12V-Output-Semicon-1637873

3pcs-XH-W1302-High-Precision-Digital-Temperature-Controller-Special-For-12V-Input-12V-Output-Semicon-1637873

3pcs-XH-W1302-High-Precision-Digital-Temperature-Controller-Special-For-12V-Input-12V-Output-Semicon-1637873

3pcs-XH-W1302-High-Precision-Digital-Temperature-Controller-Special-For-12V-Input-12V-Output-Semicon-1637873

3pcs-XH-W1302-High-Precision-Digital-Temperature-Controller-Special-For-12V-Input-12V-Output-Semicon-1637873

Write a review

Note: HTML is not translated!
Bad Good

Shipping Time


After you successfully placed an order at RenhotecIC.com, you will receive a confirmation email with your invoice. Once your order is shipped, you will be emailed with the tracking information of your package. Also, you can choose your preferred shipping method during the checkout process. Kindly advise: please select DHL/FedEx if you need our product urgently.

The timeline of the whole shipping process is shown below:

img

The total delivery time is calculated from the time your order is successfully placed to the time received. Total delivery time is broken down into processing time and shipping time.

Processing time: The time it takes to prepare your item(s), includes preparing your items, performing quality inspections, and packaging for shipment. Normally, the processing time is 1-3 days (Only include Monday to Saturday ) after getting your order.

Shipping time: The time for your item(s) to travel from our warehouse to your destination. The shipping time depends on the shipping method you chose. Please refer to the shipping rate section for details. 


Shipping Rates


You could choose the shipping method based on your preference during checkout, different shipping methods will apply different rates and shipping times. Please check the following chart for detail:


Shipping MethodShipping RatesShipping Times
Flat Shipping (Promotion)
$10About 5-30 Working Days to Worldwide (Only include Monday to Saturday )

Standard Express(0.5KG starting price listed)

Based On WeightsAbout 5-15 Working Days to Worldwide (Only include Monday to Saturday )

Priority Express (0.5KG starting price listed)

Based On WeightsAbout 3-7 Working Days to Worldwide (Only include Monday to Saturday )

In addition, the transit time depends on where you're located, the shipping method you choose, and where your package comes from. We will keep you informed of any problems here to help you get your order as soon as possible. 

If you want to know more information, please contact the customer service by contact form or sales@renhotecic.com. We will settle your problem as soon as possible. Enjoy shopping!